THE COMPANY ADHERES TO THE BELIEF OF "BEING VIRTUOUS AND CONSIDERATE, AND CREATING VALUE FOR CUSTOMERS".

ASTM D2241 Upvc Pressure pipe

_0001_7G3A8223 拷贝
_0000_II3A5791 拷贝
_0002_7G3A8222 拷贝
_0003_7G3A8220 拷贝
_0004_7G3A8217 拷贝
_0001_7G3A8223 拷贝
_0000_II3A5791 拷贝
_0002_7G3A8222 拷贝
_0003_7G3A8220 拷贝
_0004_7G3A8217 拷贝
UPVC PIPE SERIE

ASTM D2241 Upvc Pressure pipe

(Received 0+ positive customer reviews)

Product Description

ASTM D2241 uPVC Pressure Pipe is a durable and corrosion-resistant piping solution designed for pressure water supply and distribution systems. It offers smooth water flow, easy installation, and excellent long-term performance. Manufactured to meet ASTM D2241 requirements, it is available in various SDR sizes and pressure ratings for residential, agricultural, commercial, and industrial applications.


Product Details

Product Description

Product Name

Jianlong ASTM D2241 UPVC Pressure Pipe

Raw Material

PVC-U (Unplasticized Polyvinyl Chloride)

Color

White,grey,blue,orange,brown or customized

Length

10ft,20ft,5.8m,11.9m or customized

Pressure

Sdr64,Sdr41,Sdr32.5,Sdr26,Sdr21,Sdr17,Sdr13.5

Specification 

1/2“-24”

Standard

ASTM D2241

Application

Potable and cold water supply

Irrigation and agricultural water systems

Residential and commercial water distribution

Industrial water piping

Underground pressure piping

Water treatment and distribution systems      

Connection

Rubber ring joint,Solvent cement joint

Certificate

NSF61

Package

Plastic film,woven bag,wooden frame, iron frame



Product Features
PVC-U  PRESSURE  PIPE  ASTM  D2241
Size
(inch)
OD
(MM)
SDR64SDR41SDR32.5SDR26SDR21SDR17SDR13.5
Well ThicknessWell ThicknessWell ThicknessWell ThicknessWell ThicknessWell ThicknessWell Thickness
1/221.34 





1.57 
3/426.67 



1.52 1.57 1.98 
33.4 


1.52 1.6 1.96 2.46 
1-1/442.16 

1.52 1.63 2.01 2.49 3.12 
1-1/248.26 

1.52 1.85 2.29 2.84 3.58 
60.32 

1.85 2.31 2.87 3.56 4.47 
2-1/273.02 

2.24 2.79 3.48 4.29 5.41 
88.9 
2.16 2.74 3.34 4.24 5.23 6.58 
3-1/2101.6 
2.49 3.12 3.91 4.83 5.97 7.52 
114.3 
2.79 3.51 4.39 5.44 6.73 8.46 
141.3 1.78 3.45 4.34 5.44 6.73 8.31 10.46 
168.28 2.21 4.11 5.18 6.48 8.03 9.91 12.47 
219.08 2.64 5.33 6.73 8.43 10.41 12.9 
10 273.05 3.43 6.65 8.41 10.49 12.98 16.05 
12 323.85 4.27 7.9 9.96 12.45 15.39 19.05 
14 355.6 5.05 8.66 10.92 13.67 16.92 20.9 
16 406.4 
9.91 12.5 15.62 19.35 23.9 



Application Scenarios


1. Potable and Cold Water Supply

ASTM D2241 uPVC Pipe is suitable for pressurized potable and cold water supply systems where the pipe meets applicable certification and local code requirements. Its smooth inner surface helps maintain efficient water flow, while its resistance to corrosion, rust, and scaling supports reliable long-term water distribution.

2. Irrigation and Agricultural Water Systems

ASTM D2241 uPVC Pipe is widely used in agricultural irrigation systems to transport water from wells, reservoirs, pumps, and storage tanks to farmland. Its lightweight construction makes transportation and installation easier, while its pressure-rated design provides reliable performance for sprinkler, drip, and other irrigation applications.

3. Residential and Commercial Water Distribution

The pipe can be used for pressurized cold water distribution in residential buildings, commercial properties, and other facilities. Its smooth bore helps reduce friction losses and supports efficient water delivery, while its lightweight and corrosion-resistant construction makes installation and maintenance more convenient.

4. Industrial Water Piping

ASTM D2241 uPVC Pipe provides a practical solution for industrial water piping applications, including process water, cooling water, and general-purpose water supply. Its resistance to corrosion and many common chemicals makes it suitable for compatible fluid-handling environments where temperature and chemical conditions are within the pipe's service limits.

5. Underground Pressure Piping

ASTM D2241 uPVC Pipe is well suited for underground pressure water lines and buried distribution networks. Its resistance to rust and corrosion helps provide dependable performance in buried environments, while its lightweight construction can reduce handling and installation requirements compared with many traditional piping materials.

6. Water Treatment and Distribution Systems

ASTM D2241 uPVC Pipe can be used in water treatment and distribution facilities to transport compatible water between pumps, storage tanks, treatment units, and distribution networks. Its smooth internal surface supports efficient fluid flow, while its corrosion resistance helps provide a durable piping solution for long-term water infrastructure.

 


Key Advantages of UPVC Pipes


1. Lightweight

Unit weight is only 1/6 that of cast iron pipes, facilitating easy handling and transport.

UPVC density: 1,350–1,550 kg/m³ vs. ductile iron: ~7,050 kg/m³. A DN400 UPVC pipe requires only 4 workers for transport and installation, with each joint completed in ~10 minutes. Ductile iron pipe (Class K9) of the same diameter is virtually uninstallable without heavy machinery—particularly advantageous in rugged terrain or remote areas. Transport costs reduced by 50–66%.

2. Low Flow Resistance

Smooth inner wall prevents scaling; friction loss is over 30% lower than cast iron pipes.

Roughness coefficient: n=0.009, substantially lower than metallic pipes. Under identical diameter and flow conditions, head loss per unit length is significantly reduced, lowering pump head requirements and energy consumption. Flow capacity increased by 30% compared with cast iron pipes of the same diameter.

3. High Mechanical Strength

Excellent pressure rating, impact resistance, and tensile strength. Low modulus of elasticity provides superior seismic performance.

As a flexible pipe,the low modulus also dampens water hammer and pressure surge effects. Widely applied in pressure classes ranging from 0.2 to 2.5 MPa.

4. Corrosion Resistance

Outstanding resistance to inorganic acids, alkalis, salts, and chemicals; unaffected by moisture or soil pH.

No anti-corrosion coating required. Maintenance costs are only 30% of cast iron pipes. Ideal for industrial wastewater discharge and highly corrosive environments such as seawater aquaculture.

5. Easy Installation

Flexible EPDM rubber ring joints or solvent cement joints enable rapid assembly.

Correctly installed joints are leak-proof. Systems can be commissioned immediately upon successful pressure testing, significantly shortening construction schedules.

6. Long Service Life

Designed service life of 50+ years under normal operating pressure.

Excellent aging resistance, immune to bacterial and biological attack, ensuring long-term, reliable water transmission.

7. Non-Toxic and Hygienic

Manufactured with lead-free, environmentally friendly calcium-zinc stabilizers, fully compliant with national drinking water hygiene standards.

UPVC is nutritionally inert to microorganisms. The smooth bore inhibits sludge accumulation and tuberculation, preventing secondary contamination. Jianlong UPVC pipes have achieved full lead-free production.

8. Cost-Effective

Lower material, transport, and installation costs, combined with extended service life, deliver significant economic benefits.

Total project costs are 30–40% lower than cast iron systems. Maintenance costs are only 30% of cast iron, and labor costs are substantially reduced.



Install



Packaging and Delivery


Quality control and testing


Table 7 Physical and Mechanical Properties
projectRequireTest methods
density1350 kg/m³~1460 kg/m³See 8.4
Vicat softening temperature≥80℃See 8.5
Longitudinal shrinkage rate °≤5%See 8.6
Tensile yield stress≥45 MPaSee 8.7
Elongation at break≥80%See 8.8
Light transmittance≤0.2%See 8.9
Drop hammer impact (in TIR)≤5%See 8.10
Applicable only to e. Pipes ≤16mm. Applicable only to pipes marked "Opaque". Exposed pipes should be opaque.

hydrostatic strength

The hydrostatic strength of the pipe should meet the requirements of Table 8.

Table 8 (Static)liquidPressurepowerfulSpend
Nominal outer diameter d./mmTest parametersRequireTest methods
Test temperature / °CTest time/hCircumferential stress/MPa
dₙ<4020 36 No cracks, no leaksSee 8.11
dn≥4020 38 
All specifications20 100 30 
60 1000 10 

6.6Pipe socket hydrostatic strength

The hydrostatic strength of the pipe socket is only applicable to sockets with elastic sealing rings and should meet the requirements of Table 9.


Nominal outer diameter d,/mmTest parametersRequireTest methods
Test temperature / °CTest time/hTest pressure/MPa
dₙ≤9020 3.8×PNNo cracks, no leaksSee 8.12
da>903.04×PN

6.7Hygiene requirements

6.7.1 The vinyl chloride monomer content of pipes used for conveying drinking water shall not exceed 1.0 μg.g/g6.7.2 The sanitary requirements for pipes used to transport drinking water shall comply with... combineGB/T 17219According to the regulations.

Nominal outer diameter d./mmM-ClassH-class
mass/kgHeight/mmmass/kgHeight/mm
20 0.5 400 0.5 400 
25 0.5 500 0.5 500 
32 0.5 600 0.5 600 
40 0.5 800 0.5 800 
50 0.5 1000 0.5 1000 
63 0.8 1000 0.8 1000 
75 0.8 1000 0.8 1200 
90 0.8 1200 1.0 2000 
110 1.0 1600 1.6 2000 
125 1.25 2000 252000 
140 1.6 1800 3.2 1800 
160 1.6 2000 3.2 2000 
180 2.0 1800 4.0 1800 
200 2.0 2000 4.0 2000 
225 2.5 1800 5.0 1800 
250 2.5 2000 5.0 2000 
280 3.2 1800 6.3 1800 
≥3153.2 2000 6.3 2000 



FAQ
1.Do UPVC pipes buried underground require anti-corrosion treatment?

UPVC pipes offer excellent chemical corrosion resistance and are unaffected by moisture or soil pH levels, thus requiring no anti-corrosion treatment. However, care must be taken to remove stones from the trench bottom and lay a sand bed of at least 15 cm before pipe installation to prevent damage from sharp objects.

 

2.What is the service life of UPVC water supply pipes?

Under normal operating pressure and applicable temperature ranges, the design service life is 50 years. Actual service life may vary depending on installation quality, operating pressure, temperature, and other factors.


3.What are the main causes of leakage in solvent cement joints?

Inferior or expired cementing materials

Improperly cleaned joint surfaces (presence of moisture, oil, or dust)

Uneven or insufficient application of solvent cement

Failure to chamfer the pipe spigot end

Incomplete insertion — spigot not pushed to the bottom mark

Moving the pipe before adequate curing time

Construction at excessively low temperatures (below -10°C is not recommended)


4.What should be noted regarding trenching and backfilling?

Stones at the trench bottom must be removed and a sand bed of at least 15 cm laid before pipe installation. Pipes must not be laid directly on rocks.

During backfilling, large bricks or stones must not be thrown directly onto the pipes.

Backfill material should be compacted in accordance with specifications.


Product Reviews

WRITE A REVIEW

5.0

(Received 0+ positive customer reviews)

0

Total Review

0%

Would Recommend

Leave a Message

Account Login

In order to protect our patents, if you want to view the latest products, please contact us by email to obtain the login password.

pop

+86 13863300809

+86 13863300809

Jianlong@sdjlplastic.com